BT-SFT-GRJ45
- Home
- BT-SFT-GRJ45
10/100/1000 BASE-T SFP Copper Transceiver with SGMII interface BT-SFT-GRJ45 series
BT-SFT-GRJ45 10/100/1000 BASE-T copper SFP transceiver is high performance, cost effective module compliant with the Gigabit Ethernet and 1000BASE-T standards as specified in IEEE 802. 3-2002 and IEEE 802.3ab, which supporting 1000Mbps data- rate up to 100 meters reach over unshielded twisted-pair category 5 cable. The BT-SFT-GRJ45 supports1000 Mbps full duplex data-links with 5-level Pulse Amplitude Modulation (PAM) signals. All four pairs in the cable are used with symbol rate at 250Mbps on each pair. The BT-SFT-GRJ45provides standard serial ID information compliant with SFP MSA, which can be accessed with address of A0h via the 2-wire serial CMOS EEPROM protocol. The physical IC can also be accessed via 2-wire serial bus at address ACh.
- Up to 1.25Gb/s bi-directional data links
- Hot-pluggable SFP footprint
- Fully metallic enclosure for low EMI
- Low power dissipation
- Compact RJ-45 connector assembly
- Detailed product information in EEPROM
- +3.3V single power supply
- Access to physical layer IC via 2-wire serial bus
- 10/100/1000 BASE-T operation in host systems with SGMII interface
- Compliant with SFP MSA
- Compliant with IEEE Std 802.3TM-2002
- Compliant with FCC 47 CFR Part 15, Class B
- RoHS6 Compliant
SFP to Host Connector Pin Out
Pin |
Signal name |
Description |
MSA Notes |
1 |
VEET |
Transmitter ground (common with receiver ground) |
|
2 |
TFAULT |
Transmitter Fault. Not supported |
Note 1 |
3 |
TDIS |
Transmitter Disable. PHY disabled on high or open |
Note 2 |
4 |
MOD_DEF(2) |
Module Definition 2. Data line for Serial ID. |
Note 3 |
5 |
MOD_DEF(1) |
Module Definition 1. Clock line for Serial ID. |
Note 3 |
6 |
MOD_DEF(0) |
Module Definition 0. Grounded within the module. |
Note 3 |
7 |
Rate Select |
No connection required |
|
8 |
LOS |
Loss of Signal - High Indicates Loss of Signal |
Note 4 |
9 |
VEER |
Receiver Ground (common with transmitter ground) |
|
10 |
VEER |
Receiver Ground (common with transmitter ground) |
|
11 |
VEER |
Receiver Ground(common with transmitter ground) |
|
12 |
RD- |
Receiver Inverted DATA out. AC Coupled |
Note 5 |
13 |
RD+ |
Receiver Non-inverted DATA out. AC Coupled |
Note 5 |
14 |
VEER |
Receiver Ground (common with transmitter ground) |
|
15 |
VCCR |
Receiver Power Supply |
Note 6 |
16 |
VCCT |
Transmitter Power Supply |
Note 6 |
17 |
VEET |
Transmitter Ground (Common with Receiver Ground) |
|
18 |
TD+ |
Transmitter Non-Inverted DATA in. AC Coupled. |
Note 7 |
19 |
TD- |
Transmitter Inverted DATA in. AC Coupled. |
Note 7 |
20 |
VEET |
Transmitter Ground(common with receiver ground) |
SFP to host connector pin assignments and descriptions
Notes:
- 1. TX Fault is not used and is always tied to ground through a 100 ohm resistor.
- 2. TX Disable as described in the MSA is not applicable to the 1000BASE-T module, but is used for convenience as an input to reset the internal ASIC. This pin is pulled up within the module with a 4.7 KW resistor.
Low (0 – 0.8 V): Transceiver on Between (0.8 V and 2.0 V): Undefined
High (2.0 – 3.465 V): Transceiver in reset state Open: Transceiver in reset state - 3. Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7-10 KW resistor on the host board to a supply less than VCCT + 0.3 V or VCCR + 0.3 V.
Mod Def 0 is tied to ground through a 100 ohm resistor to indicate that the module is present.
Mod-Def 1 is clock line of two wire serial interface for optional serial ID
Mod-Def 2 is data line of two wire serial interface for optional serial ID - 4. LVTTL compatible with a maximum voltage of 2.5V. Not supported on NSF-SFP-T
- 5. RD-/+: These are the differential receiver outputs. They are AC coupled 100 ohm differential lines which should be terminated with 100 ohm differential at the user SerDes. The AC coupling is done inside the module and is thus not required on the host board. The voltage swing on these lines will be between 370 and 2000 mV differential (185 – 1000 mV single ended) when properly terminated. These levels are compatible with CML and LVPECL voltage swings.
- 6. VCCR and VCCT are the receiver and transmitter power supplies. They are defined as 3.3 V ± 5% at the SFP connector pin. The maximum supply current is about 300mA and the associated in-rush current will typically be no more than 30 mA above steady state after 500 nanoseconds.
- 7. TD-/+: These are the differential transmitter inputs. They are ac coupled differential lines with 100 W differential termination inside the module. The ac coupling is done inside the module and is thus not required on the host board. The inputs will accept differential swings of 500 – 2400 mV (250 –1200 mV single ended), though it is recommended that values between 500 and 1200 mV differential (250 – 600 mV single ended) be used for best EMI performance. These levels are compatible with CML and LVPECL voltage swings.
+3.3V Volt Electrical Power Interface
The BT-SFT-GRJ45 has an input voltage range of 3.3 V +/- 5%. The 4 V maximum voltage is not allowed for continuous operation.
Parameter |
Symbol |
Min. |
Typical |
Max. |
Units |
Notes/Conditions |
Supply Current |
Is |
320 |
375 |
mA |
1.2W max power over full range of voltage and temperature. See caution note below |
|
Input Voltage |
Vcc |
3.13 |
3.3 |
3.47 |
V |
Referenced to GND |
Surge Current |
Isurge |
30 |
mA |
Hot plug above steady state current. See caution note |
Caution: Power consumption and surge current are higher than the specified values in the SFP MSA +3.3 Volt electrical power interface
Low-Speed Signals
MOD_DEF (1) (SCL) and MOD_DEF (2) (SDA), are open drain CMOS signals. Both MOD_ DEF (1) and MOD_DEF (2) must be pulled up to host_Vcc.
Parameter |
Symbol |
Min. |
Max. |
Units |
Notes/Conditions |
SFP Output LOW |
VOL |
0 |
0.5 |
V |
4.7k to 10k pull-up to host_Vcc. |
SFP Output HIGH |
VOH |
host_Vcc -0.5 |
host_Vcc + 0.3 |
V |
4.7k to 10k pull-up to host_Vcc. |
SFP Input LOW |
VIL |
0 |
0.8 |
V |
4.7k to 10k pull-up to Vcc. |
SFP Input HIGH |
2 |
Vcc + 0.3 V |
V |
4.7k to 10k pull-up to Vcc. |
Low-speed signals, electronic characteristics
High-Speed Electrical Interface
All high-speed signals are AC-coupled internally.
Transmission Line-SFP |
||||||
Parameter |
Symbol |
Min. |
Typical |
Max. |
Units |
Notes/Conditions |
Line Frequency |
fL |
125 |
MHz |
5-level encoding, per IEEE 802.3 |
||
Tx Output Impedance |
Zout,TX |
100 |
Ohm |
Differential |
||
Rx Input Impedance |
Zin,RX |
100 |
Ohm |
Differential |
Host-SFP |
||||||
Parameter |
Symbol |
Min. |
Typical |
Max. |
Units |
Notes/Conditions |
Single ended data input swing |
Vinsing |
250 |
1200 |
mV |
Single ended |
|
Single ended data output swing |
Voutsing |
350 |
100 |
800 |
mV |
Single ended |
Rise/Fall Time |
Tr,Tf |
175 |
psec |
20%-80% |
||
Tx Input Impedance |
Zin |
50 |
Ohm |
Single ended |
||
Rx Output Impedance |
Zout |
50 |
Ohm |
Single ended |
Parameter |
Symbol |
Min. |
Typical |
Max. |
Units |
Notes/Conditions |
Data Rate |
BR |
100 |
1,000 |
Mb/s |
IEEE 802.3 compatible. |
|
Cable Length |
L |
100 |
M |
Category 5 UTP. BER <10-12 |
Notes:
1. Clock tolerance is +/- 50 ppm
2. By default, the HTSFP-24-1111 is a full duplex device in preferred master mode
3. Automatic crossover detection is enabled. External crossover cable is not required
4. 10/100/1000 BASE-T operation requires the host system to have an SGMII interface with no clocks, With a SERDES interface that does not support SGMII, the module will operate at 1000BASE-T only.
Environmental Specifications
The BT-SFT-GRJ45 has an extended range from 0°C to
+85°C case temperature as specified in Table 7.
Parameter |
Symbol |
Min. |
Typical |
Max. |
Units |
Notes/Conditions |
Operating Temperature |
Top |
-40 |
85 |
°C |
Case temperature |
|
Storage Temperature |
Tsto |
-40 |
100 |
°C |
Ambient temperature |
- 1.25 Gigabit Ethernet over Cat 5 cable
- Switch/Router to Switch/Router Link
- High speed I/O for file severs
Part Number |
Product Description |
BT-SFT-GRJ45 |
-5~70°C 10/100/1000Mbps Adaptive, SGMII interface, Copper SFP |
BT-SFT-IGRJ45 |
-40~85°C 10/100/1000Mbps Adaptive, SGMII interface, Copper SFP |